The valley rafter is the most complex cut in standard residential framing. The unit run is always 16.97 inches. Everything else flows from that one number.
A valley rafter runs diagonally from ridge to the inside corner where two roof planes meet. Its unit run is always 16.97″ (the diagonal of a 12″×12″ square). The plumb cut angle is the same as a common rafter at the same pitch. The cheek cut is always 45° for a regular valley on a square building with equal pitches.
A valley forms where two roof planes intersect at an inside corner — the opposite of a hip, which is an outside corner. Valley rafters carry the loads from valley jack rafters on both sides. They are structurally more heavily loaded than common rafters of the same span and must be sized accordingly.
The valley rafter runs at a 45° angle (in plan view) when the two intersecting planes have the same pitch. It rises from the inside corner of the wall plate to the ridge (or to the intersection of two ridges in a more complex roof). For equal pitches, the valley rafter’s ridge end lands at the same height as the common rafter ridge end.
On a common rafter, unit run is 12″ (by definition). On a valley rafter, unit run is the diagonal of the 12″×12″ square: √(12² + 12²) = √288 = 16.97″ (often rounded to 17″).
This means that for every 12″ of common rafter run, the valley rafter travels 16.97″ in plan. Its length is therefore longer than the common rafter by the ratio 16.97/12 = 1.414 (= √2). A house where common rafters have a 12-foot run will have valley rafters with a run of 12 × 1.414 = 16.97 feet.
Valley rafter line length = Run × Valley rafter multiplier
The valley rafter multiplier combines the 16.97″ unit run with the pitch rise:
Valley multiplier = √(16.97² + rise²) ÷ 12
| Common Pitch | Common Multiplier | Valley Rafter Multiplier | Valley: Common Ratio |
|---|---|---|---|
| 4:12 | 1.054 | 1.236 | 1.173 |
| 5:12 | 1.083 | 1.275 | 1.177 |
| 6:12 | 1.118 | 1.323 | 1.183 |
| 7:12 | 1.158 | 1.378 | 1.190 |
| 8:12 | 1.202 | 1.440 | 1.198 |
| 9:12 | 1.250 | 1.508 | 1.206 |
| 10:12 | 1.302 | 1.581 | 1.214 |
| 12:12 | 1.414 | 1.732 | 1.225 |
The valley rafter run equals the common rafter run. Multiply the run by the valley multiplier to get the valley line length before cut allowances.
The plumb cut at the ridge is made at the same angle as a common rafter for the same pitch. For 6:12: 26.6°. However, a valley rafter must also have a cheek (side) cut because it approaches the ridge (or the intersection of ridges) from a 45° angle in plan.
For a regular valley (equal pitches, square building), the cheek cut is 45°. For an irregular valley (unequal pitches), the cheek cut is not 45° and must be calculated. Use the valley rafter calculator for irregular cases.
The valley rafter has a birdsmouth where it meets the inside corner formed by two wall plates meeting at 90°. The seat cut of this birdsmouth must be level, and the heel cut must be plumb at the valley rafter’s plumb angle. The seat depth follows the same one-third rule as a common rafter (IRC R802.7.1).
The inside corner creates a practical challenge: the wall plates meeting at 90° form a tight spot where the valley rafter must fit. The birdsmouth is typically cut at the plumb cut angle (same as common rafter) with the seat running diagonally across both plates. Some framers use a doubled valley rafter (two smaller members) to simplify this detail.
Valley jack rafters frame from the valley rafter to the top plate, filling in the triangle between the valley rafter and the corner. Each valley jack rafter has a standard birdsmouth at the plate end and a compound cut at the valley rafter end (plumb cut + 45° cheek cut). The valley jack lengths follow a decreasing pattern as they approach the corner — each shorter than the last by a fixed decrement equal to the common difference for the pitch.
Enter pitch and run — get valley rafter length, multiplier, and all cut angles.
Valley rafters carry a tributary load from valley jack rafters on both sides, making them more heavily loaded than common rafters of the same span. When sizing a valley rafter:
When two roof planes intersecting at a valley have different pitches — for example, a 4:12 addition meeting a 6:12 main roof — the geometry changes significantly:
This is the most complex framing situation in standard residential roof framing. The valley rafter calculator handles equal-pitch cases; for unequal pitches, use dedicated rafter tables or structural engineering software.
What is the unit run of a valley rafter?
The unit run of a valley rafter is always 16.97 inches (often rounded to 17 inches). This is the diagonal of a 12″×12″ square: √(12² + 12²) = 16.97″.
What is the plumb cut angle for a valley rafter?
The plumb cut angle for a valley rafter is the same as for a common rafter at the same pitch. For a 6:12 roof, both the common and valley rafter plumb cuts are 26.6°. The difference is the cheek cut, which is 45° for a regular valley.
What size should a valley rafter be?
Valley rafters carry more load than common rafters and are typically sized one or two lumber sizes larger. If common rafters are 2×8, a valley rafter should be at least 2×10. For large spans or heavy loads, consult a structural engineer.
What is a cheek cut on a valley rafter?
A cheek cut (also called a side cut) is a second bevel cut perpendicular to the plumb cut that angles the rafter end so it seats flush against the ridge or hip. For a regular valley on a square building with equal pitches, the cheek cut is 45°. It is combined with the plumb cut to make a compound miter.